| Air ventilation standards and monitoring system is based on the People's Republic of China Ministry of Public Security promulgated GA124-19 EN137 96< positive pressure ventilation air fire, "the standard for the design of integrated detection device. It is designed to detect the fire brigade and rescue personnel in the use of toxic gases in the air ventilation standards of quality appliances. It will complete all major performance indicators measured ventilator, After testing the computer database for collecting and automatically deposited discrimination. 1,102,687 results will be filed. After testing respirators to ensure its reliability and safety. The test apparatus : a project to test the indicators, Dynamic detection of breathing respiratory rate 40 ± 25 min flow 100L/min flow 40 L b static test for detecting the pressure valve opening pressure and static pressure within the mask value of c, 30Mpa pressure of the pipeline leak detection can be measured within the hermetic and masks, the matching between the valve and pressure. D, residual alarm can be detected accurately measured the pressure and alarm audible alarm. The machine features : the plane gained tester features. Apart from the original design characteristics of the various functions of pressure and alarm audible alarm function. Installation of the detector, any computer can even be connected to the mainframe and test procedures. Another feature of the device is simple, just click on any item page detector can detect. If there is doubt on the test results can help click, You will be pressure on the People's Republic of China Ministry of Public Security issued a fire-related content and the standards of air respirators matter. |