Index Company Honor Product Size Order Gsbook Contact Mail 中文
Class lamps
  DF-6 Ex-portable Lights
  DF-6 Ex portable hand lamps (rechargeable type)
  HX-6800 Intense searchlight
  DF-4A Ex-intense portable work lights
  DF-4B Ex-intense work lights
  DF-4C Intense work lights
  DF-2 Ex flashlight
  DF-8 Searchlight portable explosion
  DF-10 Ex-Pan work lights
  DF-10A Repair work lights power (pan-type)
  DF-11 All automatic movements work lights
  Lifejacket lights
  Lifebuoys lights
  Liferaft lights
Fire product category
  TH Emergency escape breathing apparatus
  Long air respirators
  RHZK Pressurized air respirators Fire
  DXZ Firemen equipment
  PQ8.C Portable air bubble gun
  DTXF Fire service insulation
  Light anti-flame-retardant suit (external ventilator)
  Seal all heavy chemical warfare overalls (ventilator embedded)
  QD DC-multi-purpose water cannon spray
  Joint international strait links
  Long steel box with glass
  Firemen equipment
  Fire Equipment
  Fire extinguishers
Lifesaving equipment category
  DBF-1 Rescue service
  Marine life
  Work life
  Rescue services insulation, insulation type soaking insulation service
  DBJ-1、DBD-1 Insulation appliances
  JSQ-III、IV Hydrostatic pressure release device
  FRP tube raft storage Flantulence
  Emergency escape breathing apparatus
  Pilot Ruanti, received by escalator
  Wooden clubs and rubber clubs
  Emergency medical kits
  Liferaft rations
  Lifebuoys
  Sacrificial Anode
  Liferaft
  Liferaft F
  Lifeboat and raft sea anchor
Detection Equipment Category
  HJ-1 Comprehensive Testing Respirators
Anti-pollution equipment category
  Oil-water separator
  Sewage treatment plants
Audible signal devices category
  No. bell, No. gongs signal signal
  Since the bright orange life preserver floating lights and smoke signals
  Rope-throwing devices
  Flame rocket parachute signal
  Drifting smoke signals
  With a flame signal
  Rope equipment
 
Long air respirators
CGR-long mobile ventilator tube in the gas production and production areas in prolonged hypoxia. The environment is full of poisonous gas disaster assistance provided respiratory protection. Emergency vehicles and escape from the mobile gas cylinder components for two people to use, regional operations up 50 meters. Long attention and use air respirator use, and note 1. CGR4 × 4 precipitous 6.8/30 mobile gas cylinders cylinder group composed of two independent, Group 2 by one-way between the cylinder and pressure reducer valve control, high-pressure gas cylinders between the two groups will not arise in the back. Each cylinder can only gradually opening Group also opened all the same time, freedom to determine specific needs. A pressure relief valve in each cylinder, high-pressure pipe to vent the high-pressure gas cylinders to facilitate replacement, But no leaks under pressure reducer output of the low-pressure gas cylinders and the other gases. 2, the mobile gas cylinders through waist escape valve combined with the normal use of mobile gas directly under the gas. Need to leave the scene in case of emergencies, they can open the cylinder valve to escape to safety Strip. 3, 30 meters equipped with mobile gas source for tracheal one root, root 2 10 meters for the trachea, the largest superposition length of 50 meters. 30 meters pipe equipped with a Y-shaped links, the two officials also can be used for mobile sources of air compressed air. 4, took special use waist, suspenders, wearing the body to appropriately adjust the belts, straps, waist valve. escape bottle waist positions in the human side (note the waist valve orientation towards rapid socket above), to wear comfortable, Without prejudice to arm suitable activities. Mobile gas for the first trachea under rapid socket by the rapid upward reaches waist valve plugs. then mask-waist valve for the rapid valve inserted the plug socket. can be brought back before the movement did not wear gas masks and then first wife wrist joints directly on the valve. Mobile opened the gas cylinder valve wear breathing masks, breathing freely before entering the work site. If two people to use, and so on were all wearing full well after entering, and attention to maintaining the distance and orientation pulling for each other pipes to prevent accidents. 5, managing the use of respirators should be worn by adequate training before use. Preceded by the use of the gas pressure to meet the inspection requirements of the pressure and wear strict routine inspection found ventilator, mobile gas supply, gas supply to escape failure or hidden troubles may compel use. In the process, if you feel inadequate supply of gas, ineffective breathing, or any other discomfort, should immediately withdraw from the scene. opened the escape of gas supply or withdrawal. 6, the use of a process, the proper protection of managing mobile ventilator tube gas on the long, sharp edges and avoid long pipe for gas, Kok, corrosive media contacts or rough objects to create friction with the tractor to prevent the rule, the designated bad, scratching for trachea. If they inadvertently exposed to corrosive media, wash immediately with clean water and wipe away, a long tube defects such as gas, immediately after injury replacement. 7, if the long ventilator tube gas source close to follow the car can use, should be a separate staff to monitor custody arrangements, to check the source of gas in depleted gas issued a warning about the use of personnel and accident notification.




 
快速导航:防化服 隔热服油水分离器救生衣灯空气呼吸器消防员装备救生筏保温服空气呼吸器充气泵消防炮
Copyright © 2008 All Right Reserved. Dongtai Eastern Shipping Co., Ltd.
/**/